EXIN EPI Certified Data Centre Specialist Questions and Answers
Where should perforated tiles be installed?
A new facility requires electrical distribution of 100A to be installed in the computer room, 1 m (3 ft) above sensitive IT equipment. What type of system minimizes EMF impact?
Which formula is correct?
Can you install a raised floor tight to the perimeter of the room?
Which efficiency indicator accounts for all cooling costs (installation, operation, disposal)?
Which class of UPS is ideal for data centers?
In which stage of the data center life cycle does commissioning take place?
When designing a data center network, your company wants to minimize the number of network switches to manage.
What type of physical cabling layout would be the best choice?
The air intake of the mission-critical server at the top of the rack is measuring 25 °C/77 °F.
Is this acceptable?
The building requires sprinklers and is equipped with a wet-pipe system. What action should you recommend for the computer room?
You want to make cooling more effective by setting cold aisle temperature to 4 °C (39 °F). Is this acceptable?
The temperature in the computer room is being increased from 18°C/64°F to 27°C/81°F.
What is the impact, if any, on the amount of gas required to suppress a fire assuming the gas is a Halocarbon?
What is the focus of the Open Compute Project (OCP)?
A sprinkler system employs automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately when a head opens. What is this called?
EMF shielding material needs to be installed as EMF levels from the transformer room into the computer room are measured at 100 mG. The transformer room is ~10 meters away, separated by a corridor. Where should shielding be installed?
An MCB needs to be installed in the PDU of an air-conditioner unit.
Which breaking curve should you select?
ICT rack consumes 3 kW with ΔT ~11 °C (20 °F). Calculate required airflow (CFM).
Should aerosol cleaning solutions be used in the computer room?
What is needed to determine the Relative Humidity (RH)?
You want to manage temperature and humidity only at the facility level in your data center. All servers use front-to-rear airflow. Which location for measurement should you recommend?
Management requests a 15-minute battery bank at full UPS load. UPS specs:
30 kVA, PF 0.8
Battery 384 V (192 cells), end discharge 308 V
Inverter PF 0.8, 400 V output
What information is missing to perform the calculation?
A data center is in an area where utility power is highly available—only a few outages per year, typically <1 hour per event and <50 hours/year not available. What type of generators should be installed?
A data center has its own power supply from the public utility and receives chilled water supply from the building owner.
What needs to be taken into consideration when calculating the PUE?
Where should raised-floor installation start?
What precaution shall be taken for cabling leading into an equipment rack when a data center is in a seismic-prone area?
The UPS of a data center, with an ANSI/TIA-942 Rating-4, is installed with the rectifier connected to power feed A and the bypass/reserve line input connected to power feed B.
To which feed will the output of the UPS be synchronized?
The UPS of a data center with ANSI/TIA-942 Rating-4 is installed with the rectifier connected to power feed A and the bypass/reserve input connected to power feed B. To which feed will the UPS output be synchronized?
What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?
Do you need to consider blast protection when designing a data center?
A computer room needs to be fitted out with a gas-based fire suppression system. The computer room will be a high-density data center with about 30% of the racks being closed circuit cooling blade-center racks.
Should the supplier of the fire suppression system be informed on the design of the racks?
What is the redundancy setup shown in the diagram?
How is the PUE ratio calculated?
What is the risk of high levels of hydrogen sulfide (H₂S) in the computer room?
FM-200 is phasing out as a halocarbon gas and management has decided to replace this with the more environmentally friendly Novec-1230 gas. Should you use exactly the same formula and parameters to calculate the gas content for the Novec-1230 gas?
Smoke sensors need to be tested to ensure that they pick up a potential fire in the data center.
What should you recommend?
The temperature in the computer room is increased from 18 °C (64 °F) to 27 °C (81 °F). What is the impact on the amount of gas required to suppress a fire assuming a halocarbon agent?