HCS-Pre-sales-Digital Power V1.0 Questions and Answers
FusionModule2000UPS is listed as an integrated UPS, supporting up to 125kW
FusionModule1000A V2R3 version 40-foot IT solution can provide 7~8 IT cabinets
NetCol5000-C030H row-level chilled water precision air-conditioning fans can be maintained online, and each fan can be provided with a separate power-off switch to avoid potential safety hazards caused by direct
live maintenance.
What are the input methods supported by Huawei Magic Box power supply?
FusionModule1000A V2R3 version supports custom VESDA system
Compared with NXR, which indicators below UPS5000-A (30kVA〜120kVA) have advantages ()
UPS5000-E (50kVA power module) single rack can accommodate up to 300kVA (
The NetEco V6R8 version of the data center management system can support the access of up to 100,000 measuring points on a single server.
S5000-A Built-in Isolation Transformer
The NeEco management system supports remote notification of alarms through SMS, email, etc., prompting users to deal with alarms as soon as possible.
FusionModule1000A V2R3 version can be customized bulletproof shell
The FusionModule2000 localized power distribution cabinet has two input switches of single-channel MCCB and ATS.
Huawei's self-developed air conditioner has a 6kV lightning protection filter function, the highest in the industry
The minimum floor height of the computer room required by FusionModule2000 is 2.6 meters.
AHU can reduce PUE by applying natural cooling in high latitude regions, and can replace the chilled water solution as the main solution for large data centers ( )
How many ( ) days is the recording time of the temperature and humidity curve diagram of the inter-column air conditioner
The UPS5000-E battery adopts the design of no neutral line, which is convenient for the battery to be used when replacing the tower.
In video surveillance, if the storage time is short (one week), SD card can be configured as storage
ECC800 data room controller does not support log export ( )
Huawei air-cooled air conditioners (25kw and 42kw) one indoor unit corresponds to one outdoor unit
The minimum floor height of the Huawei FusionModule2000 installation scene is 2.6m.
Fusion Module500 & Fusion Module800 cabinet height is 24U, 42U are optional ( ).
FusionModule800 closed aisle hot and cold aisle are optional
UPS5000-E (50kVA power module) single cabinet capacity 300kVA, can support 8 racks in parallel
NetCol5000-A025H half-cabinet row-level inverter air-cooled precision air conditioner, NetCol5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner, NetCol8000-C 2.0 series room-level
refrigerated underwater air supply precision air conditioner adopts a 7-inch touch color screen, which can be intuitively Vivid display of unit operation information.
High-rate batteries have advantages in short-time discharge, and can discharge up to 90%.
The basic principles of refrigeration of air-cooled and water-cooled air conditioners are the same
FusionModule2000 sensor adopts PoE ring network power supply to improve the reliability of signal transmission in the control system, and can be used for target control.
FusionModule500 uses natural heat dissipation ( ).
The power systems of FusionModule800 and FusionMdule500 are 380/400/415/3Ph/50Hz and 220/230/240/1Ph/
50Hz respectively
Huawei air-cooled air conditioners (35kw and 46kw) - one indoor unit corresponds to one outdoor unit ( )
The row-level air conditioners (25kw and 42kw) of Huawei FusionModule2000 v3.0 have the refrigerant detection function. (
NetCol air conditioner 35kW/46kW supports linkage control of internal and external units ( ).
What are the ways of piping in FusionModule800? ( ).
The minimum ambient temperature used by FusionModule800 is ( )
The access door types of Huawei Fusionmodule2000 V3.0 version are ( )
The number of standard battery cells of a single battery pack of UPS2000-G (6-20K) is ()
The wrong description about the reliability of NetCol5000-C row-level air conditioner is: ().
What is the maximum power of the IT cabinet of FusionModule500 & FusionModule800? (
What function of NETECO needs to be used ( ) if the customer wants to know the status of the equipment on and off the shelf and the capacity of the cabinet.
UPS5000-E (50kVA power modules) 150kVA, rack 1+1 redundancy, in the total input cabinet, the required total input switch is ()
The number of single/three output channels supported by Huawei NMW smart bus is ()
How many 12v batteries can the optional battery inspection instrument of UPS5000-A-400/500K support? ( )
Regarding the cabinet rPDU of Fusionmodule2000, which of the following statements is wrong? ( )
The battery type supported by UPS2000-G is ( ).
The UPS5000E power module adopts the fan fault-tolerant design. When one of the fans is damaged, the power module can still be loaded ( ).
Which mode does the FusionModule800 UPS configuration support? (
Suppose a certain battery specification specifies that the discharge power is 400W@ 1.67V @15min, and if the system demand is 1400W. Then the number of battery packs selected is ()
Among the following models, the one with the widest input frequency range is ()
FusionModule2000 v3.0 version intelligent module status indication eLight function description is correct? (
The output power factor of UPS5000-E is as high as ( ), which can carry 11% more load than traditional UPS.
Which of the following statements is false about surveillance cameras?
There is no need to charge additional refrigerant within the length ( ) meters of the connecting pipes between the internal and external units of the FusionModule800 temperature control system.
UPS5000-E can easily realize N+X power supply system by only selecting ( ) , and the operation is simple and convenient. .
"Data Center Design Specifications" GB50174-2017 stipulates that when selecting a site, a cooling data center should have sufficient water sources.
PDU8000 precision power distribution cabinet protection level:
What kind of circuit breaker is used in the sub-circuit of PDU8000 precision power distribution cabinet: /
2GUPSS000-E (50kVA power module) 150kVA, rack 1+1 redundancy, total input power distribution cabinet, the required total input switch is ( ). /
The high-end server of NetEco6000 V6R8 version can support the access of 1 million measuring points, which is equivalent to supporting the access of () smart devices at
most?
What is the maximum IT load and how many power modules can the FusionModule2000 integrated UPS support?
Fusionllodule2000 UPS is listed, configuration (
Cabinets (racks) arranged in a row, whose length exceeds the channel between the two channels should be added. , there should be channels at both ends: when the distance between the two channels exceeds
What kind of incoming and outgoing lines can be realized by the FusionModule2000 integrated power distribution cabinet?
What is the maximum power of the IT cabinet of FusionModule500&FusionModule800?
How many power modules does the FusionModule2000 integrated UPS 50K model support?
The UPS5000-(DKVA power module) host has a small footprint, saving space in the computer room. )
The management software recommends that the optimal location of the server installation is not considered ( ).
iBattery intelligent battery management, which can monitor the parameters of a single battery in detail. What are the specific parameters? (Multiple choice)
Which of the following functions or components does the UPS6000-E (50kVA power module) come standard with? ( )
A project requires the management system to be connected to two third-party generator sets (same model) 1 ATS (same model), six precision air conditioners (same
model), and five smart meters (same model), then the management system Need to report () a third-party device access fee? ()
The following functions belong to the Fusionmodule2000 controller (ECC800) ( )
What are the fire linkage functions of FusionModule2000? (multiple choice)
UPS5000-A has the industry-leading reliability design, then which of the following is correct about the reliability design of UPS5000-A? () (multiple choice)
Huawei 25KW half-cabinet inverter air-cooled air conditioner, the following description is correct (multiple choice)
Which of the following UPS does not have a neutral line ().
For large-scale data center power distribution rooms, when configuring upper air conditioners, the elements for selecting hood air supply and air duct air supply mainly include ().(Multiple choices)
Which of the following accessories in FM2000 can be adjusted in quantity ( ). /
Which of the following statements about micromodules is true? ( )
What is the wrong description about the iManager function of FusionModule2000v3.0 version?
Among the following options, which statement is correct about the reliability of UPS5000-A (30kVA~ 120kVA) ( )
The characteristics of UPS5000-A-400/500K in terms of ease of use, which of the following are correct
Which of the following voltage systems does the UPS5000-E support?
The most energy-saving humidification method is () selection.
Which of the following models has the widest input voltage range and is more suitable for harsh power grids? (
What are the i3 features of FusionModule2000 V3.0 version?
Huawei's I Cooling. The energy-saving effect is () %. /
Load 120kW, use UPS5000-S to meet N+2 modular redundancy configuration, can be configured ( ) kVA models+
UPS000-E has reliable, efficient and simple design features, then which of the following statements about UPS5000-E-400/500K is true ( )
In the UPS5000 configurator, the optional module types are (
The power supply architecture supported by the new room and air-cooled series is ()
Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, each rack has 3 groups of batteries, each group is 30, and the
capacity of the main switch box is ( )
FusionModule2000 product configuration framework, including which of the following (
Which of the following is correct about the FM800 working condition ( )
UPS5000- has the function of adjustable number of battery cells, to avoid the replacement of gangs caused by a single battery failure, and to solve the problem of difficult maintenance of traditional UPS batteries.
How many adjustable batteries does UPS5000-E (50kVA module) support? ( )
The NetEco6000 management system can provide the following access control card readers ( ).
Which of the following measures does the NetEco management system take to ensure the security of the software platform and prevent the leakage of sensitive business data?
Which of the following functions need corresponding hardware support? ().