Winter Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dumps65

VMware 5V0-21.21 Dumps

Page: 1 / 7
Total 66 questions

VMware HCI Master Specialist Questions and Answers

Question 1

Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this message displayed:

The increase in latency in the vSAN stack might be beyond expected limits.

Which two root causes can be identified to help remediate the issue? (Choose two.)

Options:

A.

vSAN VMKemel portgroup is configured with the “Route based on IP hash” teaming policy

B.

vSAN encryption is enabled

C.

Large packet losses and retransmissions on the network layer

D.

Incorrect sizing of the disk groups capacity disks

E.

One or more disk groups are congested

Question 2

An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.

Which additional step should the administrator take to ensure no data is lost during the encryption process?

Options:

A.

Select ‘Erase disks before use’ check box when enabling encryption on a vSAN cluster.

B.

Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.

C.

Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.

D.

Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.

Question 3

A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.

The following requirements must be met:

* Each MSSQL cluster is made up of 3 nodes

* Highest possible availability against node failures

* Some of the vSAN clusters will only consume storage

What should the architect recommend?

Options:

A.

vSAN iSCSI Target Service

B.

Stretched vSAN Cluster

C.

vSAN Direct

D.

vSAN File Services

Question 4

An architect is designing a vSAN cluster.

Which storage controller option will yield optimal performance?

Options:

A.

Hugh queue depth

B.

Set caching to 50% read on the controller

C.

Enable battery write-back caching

D.

RAID 0

Question 5

A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.

During the discovery phase, the consultant found the following information about the existing environment:

* The vCenter Server is currently version 7.0.

* The vSAN Cluster has the following configuration:

- vSAN version: 7.0

- Number of vSAN nodes: 6

- Encryption: enabled

- Deduplication and Compression: enabled

- Fault Domains: 1

- vSAN Capacity Utilization: 60%

* Each vSAN node has the following configuration:

- ESXi version: VMware vSphere 7.0

- CPU: 2 processors, 20 cores

- RAM: 1024GB RAM.

- Disk: 2 Cache SSDs and 6 Capacity SSDs

- Network: 4 x 10GbE

* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.

Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

Options:

A.

Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).

B.

Disable vSAN Encryption before starting the upgrade process.

C.

Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).

D.

Set VMware Distributed Resource Scheduling (DRS) to partially automated.

E.

Upgrade to VMware vCenter Server 7.0 U1.

F.

Choose the Allow reduced redundancy option.

Question 6

Which flash disk size is required for the cache tier per ESXi node to meet all requirements?

Options:

A.

400GB

B.

700GB

C.

600GB

D.

800GB

Question 7

An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.

Which solution mandates the use of VMware vSAN?

Options:

A.

VMware Cloud Foundation

B.

VMware Horizon

C.

VMware Tanzu

D.

VMware vRealize Automation

Question 8

A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.

The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:

* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding

* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring

* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring

* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring

During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:

* Preferred Site - Preferred Site workloads should run on DC1 hosts.

* Secondary Site - Secondary Site workloads should run on DC2 hosts.

Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

Options:

A.

Change the Site Disaster Tolerance setting in Policy 3 to be “Dual Site Mirroring”.

B.

Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.

C.

Change the Site Disaster Tolerance setting in Policy 4 to be “None - Keep Data on Preferred”.

D.

Change the FTT setting in Policy 3 to be “Erasure Coding”.

E.

Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.

Question 9

An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.

Which VMware product should the administrator install as the Kubernetes platform choice?

Options:

A.

VMware Tanzu Kubernetes Grid

B.

VMware Tanzu Data services

C.

VMware Tanzu Build service

D.

VMware Tanzu Mission Control

Question 10

In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

Options:

A.

SFTT = 0

B.

SFTT = 1

C.

PFTT = 1

D.

PFTT = 0

Question 11

An administrator has noticed that a number of the virtual machines in the preferred site are showing as either failed or partitioned.

In which two ways would the administrator expect the virtual machines to respond? (Choose two.)

Options:

A.

They will be disconnected.

B.

They will be restarted in the secondary site.

C.

They will be restarted at the preferred site.

D.

They will be powered off.

E.

They will be removed from inventory.

Question 12

An architect intends to use the Primary Level of Failures To Tolerate (PFTT) to calculate the minimum number of required hosts for a vSAN cluster.

Which calculation model should be used?

Options:

A.

1 * PFTT + 1

B.

2 * PFTT + 2

C.

1 * PFTT + 2

D.

2 * PFTT + 1

Question 13

An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.

What is the minimum number of vSAN nodes required?

Options:

A.

6

B.

4

C.

5

D.

8

Question 14

An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:

* Maximize the vSAN datastore usable capacity.

* Deduplication and compression are required to help utilize available capacity efficiency.

* Ensure the highest level of resiliency wherever possible.

Which disk group configuration should the architect include in the design?

Options:

A.

One disk group per host, with one cache tier flash disk and four capacity tier flash disks.

B.

Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.

C.

Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.

D.

Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.

Question 15

An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.

Which requirement is specifically needed for these devices?

Options:

A.

Write endurance

B.

IOPS

C.

Read endurance

D.

Capacity

Question 16

In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

Options:

A.

100% of the reads comes from vSAN hosts on the local site

B.

50% of the reads comes from vSAN hosts on the local site

C.

100% of the reads comes from vSAN hosts on the remote site

D.

50% of the reads comes from vSAN hosts on the remote site

Question 17

An administrator is setting up vSAN file services on a vSAN cluster.

Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

Options:

A.

Forged Transmits

B.

Promiscuous Mode

C.

DVFiltering

D.

Jumbo Frames

E.

MacLearning

Question 18

An architect is tasked with designing a solution that includes the following requirements:

• The solution must support 5,000 virtual machines.

• The solution must include software defined storage.

• The deployment of the solution must be automated.

• The solution must provide storage-policy based disaster recovery for all workloads.

Which combination of three products will fulfill these requirements? (Choose three.)

Options:

A.

VMware Site Recovery Manager

B.

VMware Cloud Foundation

C.

VMware vRealize Automation

D.

VMware ESXi

E.

VMware vSAN

F.

VMware vSphere Replication

Question 19

A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.

During the discovery phase, the consultant found the following information about the existing environment:

* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.

* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.

* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.

* The vSAN Cluster has the following configuration:

- vSAN version: 6.6.1

- Number of vSAN nodes: 10

- Encryption: enabled

- Deduplication and Compression: enabled

- vSAN Capacity Utilization: 60%

* Each vSAN node has the following configuration:

- VMware vSphere ESXi version: 6.5 Update 3

- CPU: 2 processors, 20 cores

- RAM: 768GB RAM.

- Disk: 2 Cache SSDs and 6 Capacity SSDs

- Network: 4 x 10GbE

Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

Options:

A.

The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.

B.

The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.

C.

The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).

D.

The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.

E.

The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).

F.

The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.

Page: 1 / 7
Total 66 questions