Black Friday Biggest Discount Flat 70% Offer - Ends in 0d 00h 00m 00s - Coupon code: 70diswrap

VMware 5V0-22.23 Dumps

Page: 1 / 8
Total 75 questions

VMware vSAN Specialist v2 Questions and Answers

Question 1

A three-node vSAN OSA cluster with business critical intensive I/O workload is running out of capacity. Each host consists of five disk groups with four capacity disks. The administrator needs to expand the capacity of the vSAN datastore as soon as possible.

What should the administrator do?

Options:

A.

Enable Deduplication and Compression on the cluster level

B.

Add additional capacity by adding a disk on one host and creating a storage pool

C.

Add additional capacity by addinga vSAN ReadyNode to the cluster

D.

Add additional capacity disks to each disk group

Question 2

An administrator is responsible for managing a five-node vSAN cluster. The vSAN Cluster is configured with both vSphere High Availability (HA) and vSphere Distributed Resource Scheduler (DRS). The vSAN Cluster is currently hosting 150 virtual machines that have consumed 60% of the usable capacity.

Each virtual machine belongs to one of the following vSAN Storage Policies:

vSANPolicy1:

Site Disaster Tolerance: None

Failures to Tolerate: 1 failure - RAID-5 (Erasure Coding)

vSANPolicy2:

Site Disaster Tolerance: None

Failures to Tolerate: No data redundancy

Following an unplanned power event within the data center, the administrator has been alerted to the fact that one host has permanently failed.

What will be the impact to any virtual machine that was running on the failed host using vSANPolicy1?

Options:

A.

Each virtual machine will be restarted on another vSAN host usingvSphere HA.

B.

Each virtual machine will be unavailable for up to 90 minutes while the automatic recovery process completes.

C.

vSAN will defer the start of the recovery process for 60 minutes, and the virtual machines will not power on until the recovery process has been completed.

D.

Each virtual machine must be restored from backup.

Question 3

A vSAN administrator needs to update vSAN from version 7.0.2 to version 8.0.

Which is the correct order to perform the update?

Options:

A.

vSphere -> vCenter -> vSAN on-disk format

B.

vSphere -> vSAN on-disk format -> vCenter

C.

vCenter -> vSphere -> vSAN on-disk format

D.

vSAN on-disk format -> vSphere -> vCenter

Question 4

A vSAN administrator is responsible for managing a customer's production vSAN cluster that is going to be used to provide SMB file shares to a number of host clients. The vSAN administrator must take action so the performance of all services in the production vSAN cluster can be monitored.

Which two services must be enabled for this monitoring to occur? (Choose two.)

Options:

A.

vSAN Performance Diagnostic Service

B.

iSCSI Target Service

C.

vSAN File Services

D.

vSAN Health Service

E.

vSAN Performance Service

Question 5

An administrator is upgrading multiple vSAN Witness nodes with vLCM (single image management) that are used for vSAN Stretched and two-node Clusters.

What two witness node types can the administrator upgrade? (Choose two.)

Options:

A.

Appliance witness node

B.

Shared witness node

C.

Nested witness node

D.

Dedicated witness node

E.

Physical witness node

Question 6

An administrator is deploying a new two-node vSAN cluster with a shared witness to a remote location.

Which requirement must be met?

Options:

A.

The ESXi hosts must have SSDs or NVMe configured for Virtual Flash File System.

B.

The ESXi host's controller cache and advanced features must be disabled.

C.

The ESXi host's drives must be configured in RAID 1 to support Failures to Tolerate of 1.

D.

The ESXi hosts must have a minimum of 64 GBs of memory.

Question 7

An administrator has deployed a new vSAN OSA cluster that contains eight hosts and needs to configure a storage policy for the currently deployed database virtual machines. The requirements state that if two hosts in the vSAN OSA cluster fail, all virtual machines are unaffected.

Which RAID configuration must the administrator use in this storage policy to achieve the best performance for the database virtual machines?

Options:

A.

RA1D-1

B.

RAID-5

C.

RAID-6

D.

RAID-0

Question 8

A host in a vSAN stretched cluster goes offline during an unplanned event.

Which action will be triggered from AQC on the vSAN cluster?

Options:

A.

AQC will trigger a vMotion of VMs that went offline.

B.

AQC will restart the VMs that went offline.

C.

AQC will recalculate the quorum on an object.

D.

AQC will create a vSAN alarm.

Question 9

A vSAN administrator has recently upgraded a vSAN cluster to 8.0 OSA and has enabled Capacity Reserve features to reduce the amount of capacity reserved for transient and rebuild operations.

Which scenario would prevent this feature from operating properly?

Options:

A.

Underutilized space is above 25-30% of the total capacity threshold.

B.

The used space on vSAN datastore exceeds the suggested host rebuild threshold.

C.

The used space on vSAN datastore exceeds the suggested slack rebuild threshold.

D.

The physical disk has reached an 80% full reactive rebalance threshold.

Question 10

An administrator is tasked to create a Kerberos secured NFS v4.1 file share.

Which information is minimally required during the configuration of the File Service?

Options:

A.

Organizational Unit, User Account, Password

B.

Active Directory Domain, User Account, Password

C.

Kerberos Server, User Account, Password

D.

Active Directory Domain. Organizational Unit, User Account. Password

Question 11

An administrator must choose between deploying a virtual witness or a physical witness for a vSAN Stretched Cluster. The administrator eventually decides to use a virtual witness.

What is a benefit of selecting this approach?

Options:

A.

Increased vSAN datastore capacity

B.

Shared metadata between separate clusters

C.

Reduced vSphere licensing

D.

Additional compute capacity for running VMs

Question 12

After a planned power outage, an administrator decided to restart the vSAN cluster manually.

What is the correct sequence of steps for the administrator to follow after powering on the ESXi hosts?

Options:

A.

1. Enable cluster member updates from vCenter Server only on one ESXi host.

2. Run the python reboot helper script only on one ESXi host to recover the cluster.

3. Exit all hosts from maintenance mode.

B.

1. Exit all hosts from maintenance mode.

2. Run the python reboot helper script only on one ESXi host to recover the cluster.

3. Enable cluster member updates from vCenter Server on all ESXi hosts.

C.

1. Exit all hosts from maintenance mode.

2. Enable cluster member updates from vCenter Server only on one ESXi host.

3. Run the python reboot helper script only on one ESXi host to recover the cluster.

D.

1. Enable cluster member updates from vCenter Server on all ESXi hosts.

2. Run the python reboot helper script on all ESXi hosts to recover the cluster.

3. Exit all hosts from maintenance mode.

Question 13

A vSAN administrator receives a request from the application team to create a virtual machine on a vSAN datastore. The requirements state that the virtual machine needs to be available quickly after a failure occurs. The solution must minimize administrative effort.

Which vSphere feature should the vSAN administrator implement?

Options:

A.

Distributed Services Engine

B.

vSphere High Availability

C.

Fault Tolerance

D.

vSphere Distributed Resource Scheduler

Question 14

A vSAN administrator of a non-internet connected vSAN environment wants to upgrade the environment from the vSAN 7.0 U3 to the vSAN 8.0 using vLCM.

Which option, if any, should be used as a depot in this case?

Options:

A.

Configure the vSphere Lifecycle Manager to download the updates from an Online Depot.

B.

Configure the vSphere Lifecycle Manager to download the updates from the VMware Depot using HTTPS.

C.

Configure the vSphere Lifecycle Manager to download updates from a local UMDS-shared repository.

D.

It is not possible to use the vSphere Lifecycle Manager on a non-internet connected environment.

Question 15

An administrator has 24 physical servers that need to be configured with vSAN. The administrator needs to ensure that a single rack failure is not going to affect the data availability. The number of racks used should be minimized.

What has to be done and configured to achieve this goal?

Options:

A.

Distribute servers across at least two different racks and configure two fault domains

B.

Configure disk groups with a minimum of four capacity disks in each server and distribute them across four racks

C.

Enable deduplication and compression

D.

Distribute servers across at least three different racks and configure three fault domains

Question 16

A vSAN administrator is using the vSAN ReadyNode Sizer to build a new environment. While entering the cluster configurations, a fellow colleague inquires about the Operations Reserve option.

What is the purpose of using this option?

Options:

A.

Provides space for internal operations

B.

Configures space for external operations

C.

Reserves space for tolerating failures

D.

Allocates space forvSAN uparades

Question 17

A vSAN administrator notices that the VMware Skyline Health: Network Latency Check reports indicate that three hosts are noncompliant.

Which action should the vSAN administrator take?

Options:

A.

Immediately reboot the non-compliant hosts

B.

Check VMKNICs, uplinks, physical switches, and associated settings

C.

Rerun the VMware Skyline Health: vSAN Cluster Partition report

D.

Place the non-compliant hosts into an isolated network partition

Question 18

What are two characteristics of the vSAN Data-At-Rest Encryption (DARE)? (Choose two.)

Options:

A.

it requires Self-Encrypting Drives in order to work.

B.

it needs to be enabled together with the vSAN Data-In-Transit encryption.

C.

it is Software Defined and works independently of the Cache or Capacity drives installed on the Nodes.

D.

it is not supported on Stretched Cluster environments.

E.

it continues to operate unaffected during downtime on vCenter Server.

Question 19

A vSAN administrator has two identical VMware vSAN clusters, one for staging workloads and another for production workloads. Due to an unforeseen capacity requirement, the vSAN administrator is tasked with merging the staging vSAN cluster into the production.

Which three actions should the vSAN administrator perform on the staging cluster prior to moving the vSAN nodes to the production cluster? (Choose three.)

Options:

A.

Disable vSAN Services

B.

Delete all Disk Groups

C.

Enable File Services

D.

Delete all partitions from the capacity disks

E.

Mark the disks for partial reservation

F.

Remove all capacity drives

Question 20

What is the purpose of the TRIM/UNMAP process?

Options:

A.

Collects vSAN log files

B.

Repairs internal cache errors

C.

Deletes orphaned snapshots

D.

Reclaims disk space

Question 21

Which vSAN maintenance mode option should be used to avoid storage policy non-compliance?

Options:

A.

Ensure accessibility

B.

Partial maintenance mode

C.

Full data migration

D.

No data migration

Question 22

A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the cluster are compliant according to the vLCM image.

A 10GB NIC on the servers is experiencing issues, and the vSAN administrator determines a new network driver will resolve the problem. Unfortunately, the required NIC driver is a newer version compared to the driver provided by the most recent Vendor Add-on.

Which action should the vSAN administrator take to ensure the latest network driver is installed on the NIC before remediation?

Options:

A.

Make sure the vLCM image is configured to use the most recent version of the Vendor Add-on

B.

Add an individual component to the vLCM image that has the updated NIC driver

C.

Remove theVendor Add-on from the vLCM image, and then manually install the network driver on the servers

D.

Modify the vLCM image to omit the NIC Driver, and then manually update the servers with the required NIC driver

Page: 1 / 8